UIS Command Component Parameters

The following tables list and describe the parameters specific to the UIS command component types for this remote device:

For more general information about UIS command component parameters, see UIS Command Components. The DG_F_DEV (Get data group from device) and DG_T_DEV (Send data group to device) command component types are configured in the template file. The other command component types are considered special and are defined in the EIE editor code. See Special UIS Command Component Types for more information.

CYUPDTPT

Update CygNet Point updates the record for a CygNet point. CYUPDTPT has the following command parameters:

Parameter Required Description

FOnErr

No

Fail cmd on update error indicates to abort the UIS command if any update errors are encountered. The errors that might come up include: if the point specified in the Fac, Serv, Site, or UDC parameters does not exist, or if the point exists in a different UIS and any messaging errors or communication failure to that service comes up.

Fac

Yes

Facility for pt identifies the facility of the point to update.

Serv

No

Service for pt identifies the SERVICE of the point to update.

Site

No

Site for pt identifies the SITE of the point to update.

UDC

Yes

UDC for pt identifies the UDC of the point to update.

UType

No

Update type indicates the type of update. Value options are 0 - 3, where 0=Completion, 1=Success, 2=Failure, 3=Creation.

UsrMsk

No

User bit mask specifies the user bit mask of the point to update.

UsrVal

No

User bit value to match specifies the user bit value to match when updating the point record.

Value

No

Value indicates the point value to update.

CYWAITPT

Wait for CygNet Point signals the UIS to wait to perform a command until the value of the specified CygNet point changes to a specified value.

CYWAITPT must be the first command component added to a UIS command. You cannot add other instances of CYWAITPT to a UIS command.

CYWAITPT has the following command parameters:

Parameter Required Description

Dur

Yes

Duration is the amount of time (in HH:MM:SS or HH:MM or HH) for the UIS command to wait for the point value to change before timing out.

FOnErr

No

Fail on point error indicates to abort the UIS command if any error conditions are encountered. The point errors that might come up include: if the point specified in the Fac, Serv, Site, or UDC parameters does not exist, or if the point exists in a different UIS and any messaging errors or communication failure to that service comes up.

Fac

Yes

Facility for pt identifies the facility of the point on which to wait for the point value to change before performing the UIS command.

Int

Yes

Interval indicates the frequency (in HH:MM:SS or HH:MM or HH) with which the UIS will check the point’s value to see if it has changed.

Serv

No

Service for pt identifies the SERVICE of the point on which to wait for the point value to change before performing the UIS command.

Site

No

Site for pt identifies the SITE of the point on which to wait for the point value to change before performing the UIS command.

UDC

Yes

UDC for pt identifies the UDC of the point on which to wait for the point value to change before performing the UIS command.

UsrMsk

No

User bit mask specifies the user bit mask on which to wait for the status bit change before issuing the UIS command.

Note: The user status bit parameters (UsrMsk and UsrVal) only apply to the extended status field of the point record, so they will not match anything in the base status.

UsrVal

No

User bit value to match specifies the user bit value to match before issuing the UIS command.

Value

No

Value to match specifies the value on which to wait for the point to change to before issuing the UIS command.

Note: You can set parameters for both the point user status AND point value. So you can match either one by itself, or you can specify that both must match your parameter values.

DG_T_DEV

Send data group to device sends a data group to a field device. The parent XML Element is uccSendParms. The following parameters are available for each specified data group type.

Data Group Type Parameter Required Description Value Options

CmdDev

CmdId

No

Command ID from the "commands" for a data group in the device template file.

 

EmbedParms

No

The EmbedParms parameter is used to send multiple command parameters to a UIS running on a remote device, e.g., an EDGE device.

Specify any optional command parameters and values used by the UIS command in a comma-separated list inside square brackets.

For example, [val1=1,val2=2,val3=3] or [Cnt=2,DGORD=2,DGTYPE=Dynacard]

Use this format when sending send a UIS command with multiple command parameters from the Data Group dialog box, a pre-configured command in the UIS Command dialog box, or via the API.

[val1=1,val2=2,val3=3]

FacUdc

No

Facility.UDC for Point Processing provides a means to specify a UDC to which to map the specified data point; it requires a corresponding point in the Point Service (PNT).

Strings that specify a Facility.UDC combination.

Format

No

Format of the payload data.

Options are:

  • Protobuf
  • JSON

QoS

No

QoS

Options are:

  • 0 (message delivered to the server at most once)
  • 1 (message delivered to the server at least once)
  • 2 (message delivered to the server exactly once)

QoSDef

No

Use comm default QoS.

Boolean

TopicDev

Yes

Topic device ID

 

TopicGroup

Yes

Topic group ID

 

TopicNode

Yes

Topic edge node ID

 

Value

No

Value for the Command ID

 

CmdNode

CmdId

No

Command ID from the "commands" for a data group in the device template file.

 

EmbedParms

No

The EmbedParms parameter is used to send multiple command parameters to a UIS running on a remote device, e.g., an EDGE device.

Specify any optional command parameters and values used by the UIS command in a comma-separated list inside square brackets.

For example, [val1=1,val2=2,val3=3] or [Cnt=2,DGORD=2,DGTYPE=Dynacard]

Use this format when sending send a UIS command with multiple command parameters from the Data Group dialog box, a pre-configured command in the UIS Command dialog box, or via the API.

[val1=1,val2=2,val3=3]

FacUdc

No

Facility.UDC for Point Processing provides a means to specify a UDC to which to map the specified data point; it requires a corresponding point in the Point Service (PNT).

Strings that specify a Facility.UDC combination.

Format

No

Format of the payload data.

Options are:

  • Protobuf
  • JSON

QoS

No

QoS

Options are:

  • 0 (message delivered to the server at most once)
  • 1 (message delivered to the server at least once)
  • 2 (message delivered to the server exactly once)

QoSDef

No

Use comm default QoS

Boolean

TopicGroup

Yes

Topic group ID

 

TopicNode

Yes

Topic edge node ID

 

Value

No

Value for the Command ID

 

Back to top